ENDURO GDS Gel Documentation System

•Exceptional Resolution – 5MP Scientific Camera

•Ready to Use – Ready to connect to PC out of the box

•Innovative cabinet – Built in UV transilluminator, safety shut off switch and viewing port

•Large Field of view – 20cm x 24 cm viewing area

•No focus needed – never have to touch camera

•AutoExposure – no manual manipulation of aperture or shutter speeds required.

$260.00

Grouped product items
Product Name Part # Price Image Qty
Clear gel tray. UV transmitting tray for gel handling
66-GDS-12018
$260.00
Clear gel tray. UV transmitting tray for gel handling
White light conversion tray. UV to white light conversion screen for visible dyes
66-GDS-12019
$918.00
White light conversion tray. UV to white light conversion screen for visible dyes
Blue light conversion tray. Converts UV to blue light
66-GDS-12020
$1,650.00
Blue light conversion tray. Converts UV to blue light
Thermal high density paper, 4 rolls
66-GDS-12022
$284.00
Thermal high density paper, 4 rolls

Exceptional Resolution – The standard 5MP camera is the highest resolution camera in it’s class. It provides the best image possible for qualitative work and the most data points for accurate quantitation

Ready to Use – The ENDURO™ GDS comes with camera, camera mounts, gaskets and transilluminator installed and ready to go. When you take it out of the box simply load the software from enclosed USB stick and run.

Innovative Cabinet – The light tight cabinet has a UV viewing port to allow you to view gels directly. It also has a UV cut-off switch so that if cabinet door is opened while UV is on, you will not get accidental exposure to UV light. The easy to open drawer provides access to gels for cutting out bands being viewed. All of this in a very small footprint and completely integrated cabinet.

Large Field of View – The integrated UV transilluminator has a fully visible 20 x 24cm field of view providing enough area for the largest of gels.

No Focus Needed – The smartcapture technology utilized with this system means that you never need to touch the camera. The system is pre-focused and will be in focus whether sample is directly on transilluminator or raised on a gel tray. Another feature designed for labs with multi-user environments.

Autoexposure – Innovative qualitative and control software comes with the system. The autoexposure button provides ideal imaging with a single click. You can of course manipulate exposures and images with the large standard palette of tools within product. Additionally the UV light is controlled by the software. If you do not touch unit for short period of time the UV light is automatically shut down. No more accidentally leaving UV light on over weekends or longer. This extends life of bulbs. The ENDURO™ GDS comes standard with a 2 year warranty exclusive of UV bulbs and gaskets. This is best in industry.